♦Extra smooth movement
♦Low drive & motor heating
♦Step & direction or CW/CCW control
♦DSP-based stepper control technology
♦Automatic motor identification and self configuration
♦Semi-closed chassis can adapt to harsher environment.
♦Provides energy-saving semi-automatic current lock function;
♦Built-in temperature protection and overcurrent protection.
♦3 times overload capacity, bottom cogging torque, response speed
♦Real-time automatic gain adjustment
♦Support CANopen, EthercAT to realize multi-axishigh response synchronization control
♦STO function to meet environmental protection requirements
♦Motor Enclosure Level with IP65/67, meet the waterproof and dustproof requirement
♦The common micro-motor, pulling force is second only to the 9G standard version of the servo, is currently a super good cost performance of the servo!
♦Due to the reduced pull force, the manufacturer recommends that it be used only for small electric aircraft models, not for larger fixed-wing and electric helicopters.
♦180 degrees is left and right 90 degrees, 360 degrees is not stop rotating!
♦Dual-core processing efficiency is higher, the high motor runs smoothly, the vibration when stopping is lower, and the response is faster
♦ Simple and easy-to-understand menu display
♦ The DB series plug for convenient wiring, simple operation and easy welding
♦Supports CANopen/EtherCAT bus control, Meet the needs of high-end equipment.
♦SD20 supports fully closed-loop control and gantry synchronization, and the driver can adapt to a wider range of places.
♦Pulse mode: monopulse/double-pulse/orthogonal pulse♦Signal level: 3.3~24V compatible; series resistance not necessary for the application of PLC♦Power voltage: 110-230V AC;220V AC recommended
♦Supply voltage: 24V DC, ambient temperature: +20°C, response time: 10ms, and analog output value ofmeasurement center distance are used for unspecified measurement conditions, The subiect is white ceramics
♦This is based on the FDA Standard, accordina to Laser Notice No, 50 of the FDA Standard.
♦This is the size in the measurement center distance. These values were defined by using 1/e2 (approx.13.5%) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point maybe higher than at
the point and this may affect the measurement value.
♦Pulse mode: monopulse/double-pulse/orthogonal pulse♦Signal level: 3.3~24V compatible; series resistance not necessary for the application of PLC♦Power voltage: 110-230V AC;220V AC recommended
♦Pulse mode: monopulse/double-pulse/orthogonal pulse♦Signal level: 3.3~24V compatible; series resistance not necessary for the application of PLC♦Power voltage: 24~100V DC or 18~80V AC; 48V or 60V AC recommended
♦Pulse mode: monopulse/double-pulse/orthogonal pulse♦Signal level: 3.3~24V compatible; series resistance not necessary for the application of PLC♦Power voltage: 110-230V AC;220V AC recommended
♦Pulse mode: monopulse/double-pulse/orthogonal pulse♦Signal level: 3.3~24V compatible; series resistance not necessary for the application of PLC♦Power voltage: 24~100V DC or 18~80V AC; 48V or 60V AC recommended
♦Pulse mode: monopulse/double-pulse/orthogonal pulse♦Signal level: 3.3~24V compatible; series resistance not necessary for the application of PLC♦Power voltage: 24-50V DC supply; 36 or 48V recommended